ISO/IEC Category 6a
BP24KHA6AI
For Cat 6A, from 1MHz to 250MHz, ANSI/TIA 568.2-D and ISO/IEC-11801 shares the same limit but starts to vary from 250MHz to 500MHz. Any ISO Cat 6a Component-Rated patch panel that passes ISO Cat 6a NEXT limit will at the same time pass TIA Cat 6A NEXT limit with a higher margin. ISO Cat 6a beyond TIA Cat 6A – the stricter 3dB requirement approximately contributes 30% increase on performance at 500MHz. This also means more headroom to the entire installed cabling system in field. Made in Taiwan ETL Certified ISO / TIA Cat 6a Component & Quarterly Tested 4PPoE Compliant US 9325117 B1 / US 9948033 B1 Patented
-
ISO/IEC Category 6a
SP24ZKHA6AIM
For Cat 6A, from 1MHz to 250MHz, ANSI/TIA 568.2-D and ISO/IEC-11801 shares the same limit but starts to vary from 250MHz to 500MHz. Any ISO Cat 6a Component-Rated patch panel that passes ISO Cat 6a NEXT limit will at the same time pass TIA Cat 6A NEXT limit with a higher margin. ISO Cat 6a beyond TIA Cat 6A – the stricter 3dB requirement approximately contributes 30% increase on performance at 500MHz. This also means more headroom to the entire installed cabling system in field. Made in Taiwan ETL Certified ISO / TIA Cat 6a Component & Quarterly Tested 4PPoE Compliant US 9667004 B1 / US 9325117 B1 Patented
-
ISO/IEC Category 6a
SP24ZKVA6AIM
For Cat 6A, from 1MHz to 250MHz, ANSI/TIA 568.2-D and ISO/IEC-11801 shares the same limit but starts to vary from 250MHz to 500MHz. Any ISO Cat 6a Component-Rated patch panel that passes ISO Cat 6a NEXT limit will at the same time pass TIA Cat 6A NEXT limit with a higher margin. ISO Cat 6a beyond TIA Cat 6A – the stricter 3dB requirement approximately contributes 30% increase on performance at 500MHz. This also means more headroom to the entire installed cabling system in field. Made in Taiwan ETL Certified ISO / TIA Cat 6a Component & Quarterly Tested 4PPoE Compliant US 9667004 B1 / US 9391405 B1 Patented
-
ISO/IEC Category 6a
DBP12KHA6AID
For Cat 6A, from 1MHz to 250MHz, ANSI/TIA 568.2-D and ISO/IEC-11801 shares the same limit but starts to vary from 250MHz to 500MHz. Any ISO Cat 6a Component-Rated patch panel that passes ISO Cat 6a NEXT limit will at the same time pass TIA Cat 6A NEXT limit with a higher margin. ISO Cat 6a beyond TIA Cat 6A – the stricter 3dB requirement approximately contributes 30% increase on performance at 500MHz. This also means more headroom to the entire installed cabling system in field. Made in Taiwan ETL Certified ISO / TIA Cat 6a Component & Quarterly Tested 4PPoE Compliant US 9325117 B1 / US 9948033 B1 Patented
-
ISO/IEC Category 6a
DSP12ZKHA6AID
For Cat 6A, from 1MHz to 250MHz, ANSI/TIA 568.2-D and ISO/IEC-11801 shares the same limit but starts to vary from 250MHz to 500MHz. Any ISO Cat 6a Component-Rated patch panel that passes ISO Cat 6a NEXT limit will at the same time pass TIA Cat 6A NEXT limit with a higher margin. ISO Cat 6a beyond TIA Cat 6A – the stricter 3dB requirement approximately contributes 30% increase on performance at 500MHz. This also means more headroom to the entire installed cabling system in field. Made in Taiwan ETL Certified ISO / TIA Cat 6a Component & Quarterly Tested 4PPoE Compliant US 9667004 B1 / US 9325117 B1 Patented
-
ISO/IEC Category 6a
DSP12ZKVA6AID
For Cat 6A, from 1MHz to 250MHz, ANSI/TIA 568.2-D and ISO/IEC-11801 shares the same limit but starts to vary from 250MHz to 500MHz. Any ISO Cat 6a Component-Rated patch panel that passes ISO Cat 6a NEXT limit will at the same time pass TIA Cat 6A NEXT limit with a higher margin. ISO Cat 6a beyond TIA Cat 6A – the stricter 3dB requirement approximately contributes 30% increase on performance at 500MHz. This also means more headroom to the entire installed cabling system in field. Made in Taiwan ETL Certified ISO / TIA Cat 6a Component & Quarterly Tested 4PPoE Compliant US 9667004 B1 / US 9391405 B1 Patented
-
ISO/IEC ClassEa
SP48KMCA6AIM
TIA Cat 6A channel ≠ ISO Class Ea channel ! ISO ClassEa covers TIA Cat 6A NEXT channel requirement. The difference between two standards is 1.8dB at 500MHz! A level of 1.8dB - sometimes this margin is your overall headroom you can get on the field. In other words, ISO Class Ea Feed-Through is the premium choice when it comes to channel performance. The PCBA inside the modules are covered by patent US 9391405 B1. This patent discloses a methodology to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented
-
ISO/IEC Cat 6a
SP482LKVAS6AIM
48-port in 1U saves precious rack space in Data Center. Any ISO Cat 6a Component-Rated jack that passes ISO Cat 6a NEXT limit will at the same time pass TIA Cat 6A NEXT limit with a higher margin. ISO Cat 6a beyond TIA Cat 6A – the stricter 3dB requirement approximately contributes 30% increase on performance at 500MHz. This also means more headroom to the entire installed cabling system in field. Made in Taiwan ETL Certified ISO / TIA Cat 6a Component & Quarterly Tested 4PPoE Compliant US 9391405 B1 / US 9929480 B1 Patented
-
ISO C6a w/Shutter
SP482LKVASD6AIM
48-port in 1U saves precious rack space in Data Center. Any ISO Cat 6a Component-Rated jack that passes ISO Cat 6a NEXT limit will at the same time pass TIA Cat 6A NEXT limit with a higher margin. ISO Cat 6a beyond TIA Cat 6A – the stricter 3dB requirement approximately contributes 30% increase on performance at 500MHz. This also means more headroom to the entire installed cabling system in field. Made in Taiwan ETL Certified ISO / TIA Cat 6a Component & Quarterly Tested 4PPoE Compliant US 9391405 B1 / US 9929480 B1 / US 12051872 B2 Patented
-
ISO/IEC ClassEa
SP48KMCAS6AIM
ISO ClassEa covers TIA Cat 6A NEXT channel requirement. The difference between two standards is 1.8dB at 500MHz. In other words, ISO Class Ea Feed-Through is the premium choice when it comes to channel performance. The PCBA is assembled with die-cast shell + brass housing. Double-shield protection gives 100% airtight to avoid from EMI and retains transfer impedance and coupling attenuation performance. The PCBA inside the modules are covered by patent US 9391405 B1. This patent discloses a methodology to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented
-
ISO/IEC ClassEa
SP482KICS6AIM
ISO ClassEa covers TIA Cat 6A NEXT channel requirement. The difference between two standards is 1.8dB at 500MHz. In other words, ISO Class Ea Feed-Through is the premium choice when it comes to channel performance. The PCBA inside the modules are covered by patent US 9391405 B1. This patent discloses a methodology to minimize the disturbance caused by Feed-Through connection. The wire management is made with pivot hinges at each side which would allow you to fold the hangers so as to save the shipping volume. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented
- Home Homepage
- This is HCI Company Profile
- Copper Products By Products
-
Copper Solutions By Cat. Cabling
- UTP - ISO Cat 6a Component-Rated
- STP - ISO Cat 6a Component-Rated
- UTP - ISO-11801 Class Ea Cabling
- STP - ISO-11801 Class Ea Cabling
- UTP - TIA Cat 6A Component-Rated
- STP - TIA Cat 6A Component-Rated
- UTP - TIA Cat 6A Cabling Solution
- STP - TIA Cat 6A Cabling Solution
- UTP - Super Cat 6 Component-Rated
- STP - Super Cat 6 Component-Rated
- UTP - Super Cat 6 Cabling Solution
- STP - Super Cat 6 Cabling Solution
- Fiber Optics Fiber Connectivity
- In the Know Download Catalog
- Contact Us Send us an inquiry