Feed Searched | Innovative modular plug for B2B buyers | HCI

HCI is a leading structured cabling provider in Taiwan since 1975, we have almost 50 years experience in telecommunication OEM/ODM projects.




Best Seller

Feed | Bulk USB coupler purchasing for enterprises | HCI

Located in Taiwan since 1975, HSING CHAU INDUSTRIAL CO., LTD. is a manufacturer of wireless networking components for network installation and maintenance. Their main network infrastructure and connectivity solutions include, Feed, keystone jacks, patch panels, patch cords, modular connectors, RJ45 couplers, wall outlets and faceplates, twisted pair cables, and USB couplers supporting advanced 802.3bt 100W 4PPoE, certified under IEC-60512-99-002, ideal for wholesale buyers who require the latest networking technology.

Enhance your network with HCI's world-class B2B solutions. Our U.S.-certified and patented Keystone Jacks, Patch Panels, and Patch Cords ensure superior quality. Ideal for global business buyers, our Taiwan-made RJ45 couplers and twisted pair cables offer unmatched reliability and performance for bulk purchases. HCI offers unmatched performance in networking hardware. Improve your business connectivity with our trusted, high-quality products.

HCI has been offering customers ETL certified patch panels since 1975, both with advanced technology and 48 years of experience, HCI ensures each customer's demands are met.

Result 1 - 24 of 43
12
  • ISO/IEC ClassEa
    ISO/IEC ClassEa
    SP48KMCA6AIM

    TIA Cat 6A channel ≠ ISO Class Ea channel ! ISO ClassEa covers TIA Cat 6A NEXT channel requirement. The difference between two standards is 1.8dB at 500MHz! A level of 1.8dB - sometimes this margin is your overall headroom you can get on the field. In other words, ISO Class Ea Feed-Through is the premium choice when it comes to channel performance. The PCBA inside the modules are covered by patent US 9391405 B1. This patent discloses a methodology to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6A
    Category 6A
    SP48KMCA6AM

    48-port in 1U saves precious rack space in Data Center. The Build-in wire management provides strain-relief for great support of 48pcs Cat 6A UTP cable bundles (a lot of loads!). ANSI/TIA-568.2-D Cat 6A channel performance supports all kinds of inter-connection or cross-connection you may possibly encounter on the sites. The PCBA inside the modules are covered by patent US 9391405 B1. This patent discloses a methodology to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6
    Category 6
    SP48KMCA6SM

    48-port in 1U saves precious rack space. The Build-in wire management provides strain-relief for great support of cable bundles. ANSI/TIA-568.2-D Super Cat 6 channel performance supports all kinds of inter-connection or cross-connection you may possibly encounter on the sites. The PCBA inside the modules are covered by patent US 9391405 B1. This patent discloses a methodology to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • ISO/IEC ClassEa
    ISO/IEC ClassEa
    SP48KMCAS6AIM

    ISO ClassEa covers TIA Cat 6A NEXT channel requirement. The difference between two standards is 1.8dB at 500MHz. In other words, ISO Class Ea Feed-Through is the premium choice when it comes to channel performance. The PCBA is assembled with die-cast shell + brass housing. Double-shield protection gives 100% airtight to avoid from EMI and retains transfer impedance and coupling attenuation performance. The PCBA inside the modules are covered by patent US 9391405 B1. This patent discloses a methodology to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6A
    Category 6A
    SP48KMCAS6AM

    48-port in 1U saves precious rack space in Data Center. ANSI/TIA-568.2-D Cat 6A channel performance supports all kinds of inter-connection or cross-connection you may possibly encounter on the sites. The PCBA inside the modules are covered by patent US 9391405 B1. This patent discloses a methodology to minimize the disturbance caused by Feed-Through connection. The PCBA is assembled with die-cast shell + brass housing. Double-shield protection gives 100% airtight to avoid from EMI and retains transfer impedance and coupling attenuation performance. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6
    Category 6
    SP48KMCAS6SM

    48-port in 1U saves precious rack space. ANSI/TIA-568.2-D Super Cat 6 channel performance supports all kinds of inter-connection or cross-connection you may possibly encounter on the sites. The PCBA inside the modules are covered by patent US 9391405 B1. The PCBA is assembled with die-cast shell + brass housing. Double-shield protection gives 100% airtight to avoid from EMI and retains transfer impedance and coupling attenuation performance. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • ISO/IEC ClassEa
    ISO/IEC ClassEa
    SP482KICS6AIM

    ISO ClassEa covers TIA Cat 6A NEXT channel requirement. The difference between two standards is 1.8dB at 500MHz. In other words, ISO Class Ea Feed-Through is the premium choice when it comes to channel performance. The PCBA inside the modules are covered by patent US 9391405 B1. This patent discloses a methodology to minimize the disturbance caused by Feed-Through connection. The wire management is made with pivot hinges at each side which would allow you to fold the hangers so as to save the shipping volume. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6A
    Category 6A
    SP482KICS6AM

    48-port in 1U saves precious rack space in Data Center. ANSI/TIA-568.2-D Cat 6A channel performance supports all kinds of inter-connection or cross-connection you may possibly encounter on the sites. The PCBA inside the modules are covered by patent US 9391405 B1. This patent discloses a methodology to minimize the disturbance caused by Feed-Through connection. The wire management is made with pivot hinges at each side which would allow you to fold the hangers so as to save the shipping volume. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Snap-In Type Panel
    Snap-In Type Panel
    SP482M

    48-port in 1U will save a lot of precious rack space in Data Center. SP482 offers you the possibilities to build any solution as desired. If 48-port Component-Rated Keystone LKVAS is needed, simply terminate each jack then load it on to the panel. If Feed-Through connection is more preferable, you can have 48-port Keystone Coupler KICS pre-configured. It’s really up to you to make up your own combination. The wire management is made with pivot hinges at each side which would allow you to fold the hangers so as to save the shipping volume.


  • ISO/IEC ClassEa
    ISO/IEC ClassEa
    3013AKIC6AI

    TIA Cat 6A channel ≠ ISO ClassEa channel! Everybody is talking about Cat 6A nowadays. But even the name “Cat 6A” has different definition on transmission performance. Just bear in mind that ISO/IEC 11801 Ed. 2.2 Cat 6A (a.k.a. Class Ea) is the premium choice because it requires 1.8dB stricter at 500MHz than TIA-568.2-D Cat 6A does when it comes to channel performance. The patented US 9391405 B1 design features Inductance-offset technique to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6A
    Category 6A
    3013AKIC6A

    ANSI/TIA-568.2-D Cat 6A channel performance supports all kinds of inter-connection or cross-connection you may possibly encounter on the sites. The patented US 9391405 B1 design features Inductance-offset technique to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6
    Category 6
    3013AKIC6S

    Considerations for running 802.3bz 5GBASE-T to support higher data rate of wireless AP would push the required bandwidths to 312MHz, well above the 250MHz specification of ANSI/TIA 568.2-D and ISO/IEC-11801 Category 6. HCI Unshielded Super Cat 6 keystone coupler go beyond extended bandwidth for up to 350MHz. The patented US 9391405 B1 design features Inductance-offset technique to minimize the disturbance caused by Feed-Through connection. Compact structure allows loading into 48-port in 1U high density patch panels and 6-port gang frames. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 5e
    Category 5e
    3013AKIC5eS

    HCI Unshielded Super Cat 5e keystone coupler are compatible to ANSI/TIA 568.2-D and ISO/IEC-11801 standards. Moreover, they are capable of going beyond extended frequencies to support 2.5G BASE-T. The patented US 9391405 B1 design features Inductance-offset technique to minimize the disturbance caused by Feed-Through connection. Compact structure allows loading into 48-port in 1U high density patch panels and 6-port gang frames. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6A
    Category 6A
    3013AJUQF6A

    RJ45 90 degree Unshielded Keystone jack feed-through straight keystone coupler is designed for quick installations. UTP coupler is easy to snap into the outlets and patch panels. When requirements are changed, simply disconnect the patch cord and snap out the unneeded keystone coupler. Then snap is a new one and connect the patch cord. The unique structure provides an efficient and effective method of reducing alien crosstalk from neighboring connectors.


  • Category 6
    Category 6
    3013AJUQF6

    RJ45 90 degree Unshielded Keystone jack feed-through straight keystone coupler is designed for quick installations. UTP coupler is easy to snap into the outlets and patch panels. When requirements are changed, simply disconnect the patch cord and snap out the unneeded keystone coupler. Then snap is a new one and connect the patch cord.


  • Category 5e
    Category 5e
    3013AJUQF5e

    RJ45 90 degree Unshielded Keystone jack feed-through straight keystone coupler is designed for quick installations. UTP coupler is easy to snap into the outlets and patch panels. When requirements are changed, simply disconnect the patch cord and snap out the unneeded keystone coupler. Then snap is a new one and connect the patch cord.


  • ISO/IEC ClassEa
    ISO/IEC ClassEa
    3013AKMCB6AI

    TIA Cat 6A channel ≠ ISO ClassEa channel! Everybody is talking about Cat 6A nowadays. But even the name “Cat 6A” has different definition on transmission performance. Just bear in mind that ISO/IEC 11801 Ed. 2.2 Cat 6A (a.k.a. Class Ea) is the premium choice because it requires 1.8dB stricter at 500MHz than TIA-568.2-D Cat 6A does when it comes to channel performance. The patented US 9391405 B1 design features Inductance-offset technique to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6A
    Category 6A
    3013AKMCB6A

    ANSI/TIA-568.2-D Cat 6A channel performance supports all kinds of inter-connection or cross-connection you may possibly encounter on the sites. The patented US 9391405 B1 design features Inductance-offset technique to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6
    Category 6
    3013AKMCB6S

    Considerations for running 802.3bz 5GBASE-T to support higher data rate of wireless AP would push the required bandwidths to 312MHz, well above the 250MHz specification of ANSI/TIA 568.2-D and ISO/IEC-11801 Category 6. HCI Unshielded Super Cat 6 Mobile Style Coupler goes beyond extended bandwidth for up to 350MHz. The patented US 9391405 B1 design features Inductance-offset technique to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 5e
    Category 5e
    3013AKMCB5eS

    HCI Unshielded Super Cat 5e Mobile Style Coupler is compatible to ANSI/TIA 568.2-D and ISO/IEC-11801 standards. Moreover, they are capable of going beyond extended frequencies to support 2.5G BASE-T. The patented US 9391405 B1 design features Inductance-offset technique to minimize the disturbance caused by Feed-Through connection. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6
    Category 6
    210IDB6

    180 degree Unshielded Keystone jack feed-through straight dual IDC coupler (IDB Series) provides a cable-to-cable connection for more flexible cabling application.


  • Category 5e
    Category 5e
    210IDB5e

    180 degree Unshielded Keystone jack feed-through straight dual IDC coupler (IDB Series) provides a cable-to-cable connection for more flexible cabling application.


  • ISO/IEC ClassEa
    ISO/IEC ClassEa
    3013AKICS6AI

    TIA Cat 6A channel ≠ ISO ClassEa channel! Everybody is talking about Cat 6A nowadays. Just bear in mind that ISO/IEC 11801 Ed. 2.2 Cat 6A (a.k.a. Class Ea) is the premium choice because it requires 1.8dB stricter at 500MHz than TIA-568.2-D Cat 6A does when it comes to channel performance. The patented US 9391405 B1 design features Inductance-offset technique to minimize the disturbance caused by Feed-Through connection. Compact structure allows loading into 48-port in 1U high density patch panels and 6-port gang frames. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented


  • Category 6A
    Category 6A
    3013AKICS6A

    ANSI/TIA-568.2-D Cat 6A channel performance supports all kinds of inter-connection or cross-connection you may possibly encounter on the sites. The patented US 9391405 B1 design features Inductance-offset technique to minimize the disturbance caused by Feed-Through connection. Zinc alloyed Die-Cast housing offers outstanding shield integrity and screen effectiveness that can be verified by EMI, transfer impedance and coupling attenuation performance. Compact structure allows loading into 48-port in 1U high density patch panels and 6-port gang frames. Made in Taiwan 4PPoE Compliant US 9391405 B1 Patented



Result 1 - 24 of 43
12