Cat 6A Searched | Innovative modular plug for B2B buyers | HCI

HCI is a leading structured cabling provider in Taiwan since 1975, we have almost 50 years experience in telecommunication OEM/ODM projects.




Best Seller

Cat 6A | Bulk USB coupler purchasing for enterprises | HCI

Located in Taiwan since 1975, HSING CHAU INDUSTRIAL CO., LTD. is a manufacturer of wireless networking components for network installation and maintenance. Their main network infrastructure and connectivity solutions include, Cat 6A, keystone jacks, patch panels, patch cords, modular connectors, RJ45 couplers, wall outlets and faceplates, twisted pair cables, and USB couplers supporting advanced 802.3bt 100W 4PPoE, certified under IEC-60512-99-002, ideal for wholesale buyers who require the latest networking technology.

Enhance your network with HCI's world-class B2B solutions. Our U.S.-certified and patented Keystone Jacks, Patch Panels, and Patch Cords ensure superior quality. Ideal for global business buyers, our Taiwan-made RJ45 couplers and twisted pair cables offer unmatched reliability and performance for bulk purchases. HCI offers unmatched performance in networking hardware. Improve your business connectivity with our trusted, high-quality products.

HCI has been offering customers ETL certified patch panels since 1975, both with advanced technology and 48 years of experience, HCI ensures each customer's demands are met.

Result 73 - 96 of 105
  • Cat 6A STP  Field Termination Plug
    Cat 6A STP Field Termination Plug
    88TS52G2A6ATK

    The 88TS52G2A6ATK series incorporates a two-row prewired mechanism, allowing for the convenient routing of each pair through its designated slot and effortless seating. The screw-type rotatable cable gland is specifically designed to accommodate various cable sizes, ranging from 23AWG solid to 26AWG stranded cables, irrespective of whether they are S/FTP, F/FTP, F/UTP, or U/FTP shielded types. Depending on the diameter of the cable, you have the flexibility to adjust the tightness of the attached grounding by screwing it tightly or loosely according to your requirements. The plug features a free-directional cable entrance that can easily adapt to the incoming cable. Regardless of whether the cable is routed from the top or the sides, you have the flexibility to adjust the cable patch by closing the two-piece guiding lids and rotating them as needed. The plug is compliant with the rigorous standards of IEC 60512-99-002, which guarantee its durability even during numerous mating cycles under electrical load. This compliance aligns with the compatibility requirements set forth by IEEE 802.3bt. The shielded angled type plug is designed to support 4PPoE Class 8 power levels, enabling the transmission of up to 90W of power from the Power Sourcing Equipment (PSE) to the Powered Device (PD) over four twisted pairs. Moreover, the HCI 88TK series plugs are compliant with IEC 60512-99-002 standards, ensuring durability during mating cycles under electrical load, in accordance with the compatibility requirements of IEEE 802.3bt.


  • Cat 6A U/UTP Molded Type Stranded Round Patch Cord
    Cat 6A U/UTP Molded Type Stranded Round Patch Cord
    UU01MT6AXX

    UUM Series U/UTP molded type stranded round patch cord or patch cables are electrical cables, used to connect ("patch-in") one electronic device to another for signal routing. We offer plugs in standard configurations to terminate patch cords for patching or workstation applications. Patch cords can be terminated to the exact length needed for neater, more organized installations and are RoHS compliant. Patch cords are assemblies of 4 twisted-pair 24 AWG (0.51mm) stranded wire cables with modular plugs crimped on both ends. T568A and T568B wiring schemes are both available. U.S. TAA Compliant version available upon request


  • Cat 6A U/UTP Stranded Flat Patch Cord
    Cat 6A U/UTP Stranded Flat Patch Cord
    UU01MTF6A

    UUM Series U/UTP molded type stranded round patch cord or patch cables are electrical cables, used to connect ("patch-in") one electronic device to another for signal routing. We offer plugs in standard configurations to terminate patch cords for patching or workstation applications. Patch cords can be terminated to the exact length needed for neater, more organized installations and are RoHS compliant. Patch cords are assemblies of 4 twisted-pair 24 AWG (0.51mm) stranded wire cables with modular plugs crimped on both ends. T568A and T568B wiring schemes are both available. U.S. TAA Compliant version available upon request


  • Cat 6A U/UTP Booted Type Stranded Round Patch Cord
    Cat 6A U/UTP Booted Type Stranded Round Patch Cord
    UU01AT6AXX

    UUA Series U/UTP booted type stranded round patch cord or patch cables are electrical cables, used to connect ("patch-in") one electronic device to another for signal routing. We offer plugs in standard configurations to terminate patch cords for patching or workstation applications. Patch cords can be terminated to the exact length needed for neater, more organized installations and are RoHS compliant. Patch cords are assemblies of 4 twisted-pair 24 AWG (0.51mm) stranded wire cables with modular plugs crimped on both ends. T568A and T568B wiring schemes are both available.


  • Cat 6A F/UTP Molded Type Stranded Round Patch Cord
    Cat 6A F/UTP Molded Type Stranded Round Patch Cord
    FU01MT6A

    FUM Series F/UTP molded type stranded round patch cord or patch cables are electrical cables, used to connect ("patch-in") one electronic device to another for signal routing. We offer plugs in standard configurations to terminate patch cords for patching or workstation applications. Patch cords can be terminated to the exact length needed for neater, more organized installations and are RoHS compliant. Patch cords are assemblies of 4 twisted-pair 24 AWG (0.51mm) stranded wire cables with modular plugs crimped on both ends. T568A and T568B wiring schemes are both available.


  • Cat 6A SF/UTP Molded Type Stranded Round Patch Cord
    Cat 6A SF/UTP Molded Type Stranded Round Patch Cord
    SFU01MT6AB

    Using 26 AWG (0.4mm) stranded wire SF/UTP twisted-pair patch cables and shielded plugs. Individual aluminum foil screened balanced elements provides good protection from data errors. Overall braid-screened cable helps to complete a proper ground connection. It allows long runs with less fear of EMI/RFI. Insulated with best grade of PVC or LSZH sheath.


  • Cat 6A SF/TP Molded Type Stranded Round Patch Cord
    Cat 6A SF/TP Molded Type Stranded Round Patch Cord
    SF01MT6AB

    Using 26 AWG (0.4mm) stranded wire S/FTP twisted-pair patch cables and shielded plugs. Individual aluminum foil screened balanced elements provides good protection from data errors. Overall braid-screened cable helps to complete a proper ground connection. It allows long runs with less fear of EMI/RFI. Insulated with best grade of PVC or LSZH sheath. U.S. TAA Compliant version available upon request


  • Cat 6 SF/TP Molded Type Stranded Round Patch Cord
    Cat 6 SF/TP Molded Type Stranded Round Patch Cord
    SF01MT6B

    Using 26 AWG (0.4mm) stranded wire S/FTP twisted-pair patch cables and shielded plugs. Individual aluminum foil screened balanced elements provides good protection from data errors. Overall braid-screened cable helps to complete a proper ground connection. It allows long runs with less fear of EMI/RFI. Insulated with best grade of PVC or LSZH sheath. U.S. TAA Compliant version available upon request


  • Cat 5e SF/TP Molded Type Stranded Round Patch Cord
    Cat 5e SF/TP Molded Type Stranded Round Patch Cord
    SF01MT5eB

    Using 26 AWG (0.4mm) stranded wire S/FTP twisted-pair patch cables and shielded plugs. Individual aluminum foil screened balanced elements provides good protection from data errors. Overall braid-screened cable helps to complete a proper ground connection. It allows long runs with less fear of EMI/RFI. Insulated with best grade of PVC or LSZH sheath. U.S. TAA Compliant version available upon request


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, 6-up/2-down load bar + windmill guide

    Standard Cat 6A unshielded modular plugs accept from 24AWG to 26AWG, stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. The “guide” helps to separate each pair and keep its twist ratio. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. This could provide many field installers with exactly what they need to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, one-row load bar + windmill guide

    Standard Cat 6A unshielded modular plugs accept from 24AWG to 26AWG, stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. Effective pair separation and maintaining the twist ratio are made possible by the "windmill guide". Together with the “loading bar” attached to it so each wire can be trimmed flush and steadily seated. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.95-1.05mm Insulated Conductor
    For 0.95-1.05mm Insulated Conductor
    “2pcs”, 6-up/2-down loading bar

    The Snagless Cat 6A unshielded modular plugs accept from 24AWG to 26AWG stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm. “The Snagless” prevents lots of cable snags when managing daily network distribution: move, add and change (MAC). It allows easy pulling through crowded distribution frames or cable management trays. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    Cable Range: O.D.≦6.5mm

    The Pass-Through Cat 6A unshielded modular plugs accept from 24AWG to 26AWG stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. The Pass-Through plug gives you the convenience of threading the wires through the end wall and cutting them afterward. Only a very short untwisted length is presented while the cable is fully inserted into the taper, which is the secret to Cat 6A compliance. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.70-0.80mm Insulated Conductor
    For 0.70-0.80mm Insulated Conductor
    w/SR for 4.5mm cable entrance

    The “Small Conductor” Cat 6A unshielded modular plugs accept 26AWG and 28AWG slim cables. 28AWG UTP cable has a 0.69mm insulation diameter with nominal cable O.D. from 3.5mm to 4.8mm only. The 2-piece design has a “loading-bar” to accept from 0.70 to 0.80mm insulated conductors so all the thin wires can be placed on each slot. And the loading-bar is made in two rows - “6-up/2-down”, moving the green pair away from the other pairs. 3-prong blades further enhance the certainty of piercing the slim cable so excellent conductivity can be assured. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades


  • For 0.55-0.60mm Insulated Conductor
    For 0.55-0.60mm Insulated Conductor
    w/SR for 4.0mm cable entrance

    The “Small Conductor” Cat 6A unshielded modular plugs accept 28AWG and 30AWG ultra-slim cables. 30AWG cable has nominal insulations at approximately 0.53mm only. The 2-piece design has a “loading-bar” to accept from 0.55 to 0.60mm insulated conductors so all the thin wires can be placed on each slot. And the loading-bar is made in two rows - “6-up/2-down”, moving the green pair away from the other pairs. Plug assembly that surpasses the Cat 6A specification is therefore feasible. 3-prong blades further enhance the certainty of piercing the ultra-slim cable so excellent conductivity can be assured. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades


  • For 1.00-1.10mm Insulated Conductor
    For 1.00-1.10mm Insulated Conductor
    “2pcs”, 6-up/2-down loading bar

    The “Big Conductor” Cat 6A unshielded modular plugs accept from 23 to 26AWG, U/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.00mm to 1.10mm. The 2-piece design has a “loading-bar” to accept from 1.00 to 1.10mm insulated conductors so all the wires can be placed on each slot. And the loading-bar is made in two rows - “6-up/2-down”, moving the green pair away from the other pairs. Plug assembly that surpasses the Cat 6A specification is therefore feasible. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, 1-row loading bar + windmill guide

    Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG, stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. Effective pair separation and maintaining the twist ratio are made possible by the "windmill guide". Together with the “loading bar” attached to it so each wire can be trimmed flush and steadily seated. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “2pcs”, 6-up/2-down loading bar

    Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG, stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, loading bar + windmill guide

    Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • Plug includes Boot w/Icon
    Plug includes Boot w/Icon
    Plug + φ6.7mm Boot + Boot Icon

    Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • Plug includes Boot w/Icon + Cable SR
    Plug includes Boot w/Icon + Cable SR
    Plug + φ6.7mm Boot + Boot Icon + Cable SR

    Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.95-1.05mm Insulated Conductor
    For 0.95-1.05mm Insulated Conductor
    “2pcs”, 6-up/2-down loading bar

    The Snagless Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm. 2-piece design. The loading bar is made in two rows - “6-up/2-down”. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. Each wire is trimmed flush and steadily seated. Plug assembly that surpasses the Cat 6A specification is therefore feasible. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 1.30-1.40mm Insulated Conductor
    For 1.30-1.40mm Insulated Conductor
    Cable Range: O.D.≦7.5mm

    The Pass-Through Cat 6A shielded modular plugs are made to accept 23AWG S/FTP foamed wires with accommodation of insulated conductor from 1.30mm to 1.40mm. The Pass-Through plug gives you the convenience of threading the wires through the loading bar. The “1357-up/2468-down loading bar” is made in two rows. It eases the tension throughout the assembling procedure instead of aligning in a single row. Simply insert the bar all the way till it reaches the narrow gate and cut all wires afterward. Only a very short untwisted length is presented with no room for kink and slack. The extremely short stripped length is the secret to Cat 6A compliance. The external grounding hook is built at the rear for encircling the screened braid of S/FTP cable. The 360-degree shield surrounding favors the screen effectiveness and shield integrity that high-speed Ethernet requires. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8401 Series Crimping Tool


  • For 0.55-0.60mm Insulated Conductor
    For 0.55-0.60mm Insulated Conductor
    w/SR for 4.0mm cable entrance

    The “Small Conductor” Cat 6A shielded modular plugs accept 28AWG and 30AWG ultra-slim cables. 30AWG cable has nominal insulations at approximately 0.53mm only. The 2-piece design has a “loading-bar” to accept from 0.55 to 0.60mm insulated conductors so all the thin wires can be placed on each slot. And the loading-bar is made in two rows - “6-up/2-down”, moving the green pair away from the other pairs. Plug assembly that surpasses the Cat 6A specification is therefore feasible. 3-prong blades further enhance the certainty of piercing the ultra-slim cable so excellent conductivity can be assured. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades



Result 73 - 96 of 105