For 1.05-1.15mm Insulated Conductor
“2pcs”, 4-up/4-down loading bar
The “Big Conductor” Cat 6 unshielded modular plugs accept from 24 to 26AWG, U/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.0mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“Single Piece”without loading bar
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 5.5mm. Single-piece plug is for those who are equipped with excellent workmanship on the field. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“2pcs”, 4-up/4-down loading bar
Standard Cat 6 shielded modular plugs accept 23 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“2pcs”, 6-up/2-down loading bar
Standard Cat 6 shielded modular plugs accept 23 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“3pcs”, loading bar + windmill guide
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon
Plug + φ6.7mm Boot + Boot Icon
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon + Cable SR
Plug + φ6.7mm Boot + Boot Icon + Cable SR
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
Cable Range: O.D.≦6.5mm
The Pass-Through Cat 6 shielded modular plugs accept 24AWG to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. The Pass-Through plug gives you the convenience of threading the wires through the end wall and cutting them afterward. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8401 Series Crimping Tool
-
For 0.95-1.05mm Insulated Conductor
Cable Range: O.D.≦6.5mm
The Snagless Pass-Through Cat 6 shielded modular plugs accept from 23AWG to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm and cable O.D. less than 6.5mm. “The Snagless” allows easy pulling through crowded distribution frames or cable management trays. “The Pass-Through” enables the threading of all wires through the plug's end wall for subsequent cutting. It must work with 007A8502 Series Crimping Tool for termination and cutting of wires both at once! - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8502 Series Crimping Tool
-
For 1.05-1.15mm Insulated Conductor
Cable Range: O.D.≦6.5mm
The Snagless Pass-Through Cat 6 shielded modular plugs accept from 23AWG to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. “The Snagless” allows easy pulling through crowded distribution frames or cable management trays. “The Pass-Through” enables the threading of all wires through the plug's end wall for subsequent cutting. It must work with 007A8502 Series Crimping Tool for termination and cutting of wires both at once! - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8502 Series Crimping Tool
-
For 1.05-1.15mm Insulated Conductor
“2pcs”, 4-up/4-down loading bar
The “Big Conductor” Cat 6 shielded modular plugs accept from 23 to 24AWG, F/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 1.05-1.15mm Insulated Conductor
“2pcs”, 4-up/4-down loading bar
The “Big Conductor w/Grounding Bar” Cat 6 shielded modular plugs accept from 23 to 24AWG, F/UTP and S/FTP twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. Grounding is facilitated by the external grounding bar. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“3pcs”, 6-up/2-down load bar + windmill guide
Standard Cat 6A unshielded modular plugs accept from 24AWG to 26AWG, stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. The “guide” helps to separate each pair and keep its twist ratio. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. This could provide many field installers with exactly what they need to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“3pcs”, one-row load bar + windmill guide
Standard Cat 6A unshielded modular plugs accept from 24AWG to 26AWG, stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. Effective pair separation and maintaining the twist ratio are made possible by the "windmill guide". Together with the “loading bar” attached to it so each wire can be trimmed flush and steadily seated. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.95-1.05mm Insulated Conductor
“2pcs”, 6-up/2-down loading bar
The Snagless Cat 6A unshielded modular plugs accept from 24AWG to 26AWG stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm. “The Snagless” prevents lots of cable snags when managing daily network distribution: move, add and change (MAC). It allows easy pulling through crowded distribution frames or cable management trays. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
Cable Range: O.D.≦6.5mm
The Pass-Through Cat 6A unshielded modular plugs accept from 24AWG to 26AWG stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. The Pass-Through plug gives you the convenience of threading the wires through the end wall and cutting them afterward. Only a very short untwisted length is presented while the cable is fully inserted into the taper, which is the secret to Cat 6A compliance. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 1.00-1.10mm Insulated Conductor
“2pcs”, 6-up/2-down loading bar
The “Big Conductor” Cat 6A unshielded modular plugs accept from 23 to 26AWG, U/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.00mm to 1.10mm. The 2-piece design has a “loading-bar” to accept from 1.00 to 1.10mm insulated conductors so all the wires can be placed on each slot. And the loading-bar is made in two rows - “6-up/2-down”, moving the green pair away from the other pairs. Plug assembly that surpasses the Cat 6A specification is therefore feasible. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“3pcs”, 1-row loading bar + windmill guide
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG, stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. Effective pair separation and maintaining the twist ratio are made possible by the "windmill guide". Together with the “loading bar” attached to it so each wire can be trimmed flush and steadily seated. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“2pcs”, 6-up/2-down loading bar
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG, stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“3pcs”, loading bar + windmill guide
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon
Plug + φ6.7mm Boot + Boot Icon
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon + Cable SR
Plug + φ6.7mm Boot + Boot Icon + Cable SR
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.95-1.05mm Insulated Conductor
“2pcs”, 6-up/2-down loading bar
The Snagless Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm. 2-piece design. The loading bar is made in two rows - “6-up/2-down”. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. Each wire is trimmed flush and steadily seated. Plug assembly that surpasses the Cat 6A specification is therefore feasible. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 1.30-1.40mm Insulated Conductor
Cable Range: O.D.≦7.5mm
The Pass-Through Cat 6A shielded modular plugs are made to accept 23AWG S/FTP foamed wires with accommodation of insulated conductor from 1.30mm to 1.40mm. The Pass-Through plug gives you the convenience of threading the wires through the loading bar. The “1357-up/2468-down loading bar” is made in two rows. It eases the tension throughout the assembling procedure instead of aligning in a single row. Simply insert the bar all the way till it reaches the narrow gate and cut all wires afterward. Only a very short untwisted length is presented with no room for kink and slack. The extremely short stripped length is the secret to Cat 6A compliance. The external grounding hook is built at the rear for encircling the screened braid of S/FTP cable. The 360-degree shield surrounding favors the screen effectiveness and shield integrity that high-speed Ethernet requires. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8401 Series Crimping Tool
- Home Homepage
- This is HCI Company Profile
- Products Data Connectivity
-
Solutions Transmission Category
- UTP - ISO Cat 6a Component-Rated
- STP - ISO Cat 6a Component-Rated
- UTP - ISO-11801 Class Ea Cabling
- STP - ISO-11801 Class Ea Cabling
- UTP - TIA Cat 6A Component-Rated
- STP - TIA Cat 6A Component-Rated
- UTP - TIA Cat 6A Cabling Solution
- STP - TIA Cat 6A Cabling Solution
- UTP - Super Cat 6 Component-Rated
- STP - Super Cat 6 Component-Rated
- UTP - Super Cat 6 Cabling Solution
- STP - Super Cat 6 Cabling Solution