Panel Searched | Innovative modular plug for B2B buyers | HCI

HCI is a leading structured cabling provider in Taiwan since 1975, we have almost 50 years experience in telecommunication OEM/ODM projects.




Best Seller

Panel | Bulk USB coupler purchasing for enterprises | HCI

Located in Taiwan since 1975, HSING CHAU INDUSTRIAL CO., LTD. is a manufacturer of wireless networking components for network installation and maintenance. Their main network infrastructure and connectivity solutions include, Panel, keystone jacks, patch panels, patch cords, modular connectors, RJ45 couplers, wall outlets and faceplates, twisted pair cables, and USB couplers supporting advanced 802.3bt 100W 4PPoE, certified under IEC-60512-99-002, ideal for wholesale buyers who require the latest networking technology.

Enhance your network with HCI's world-class B2B solutions. Our U.S.-certified and patented Keystone Jacks, Patch Panels, and Patch Cords ensure superior quality. Ideal for global business buyers, our Taiwan-made RJ45 couplers and twisted pair cables offer unmatched reliability and performance for bulk purchases. HCI offers unmatched performance in networking hardware. Improve your business connectivity with our trusted, high-quality products.

HCI has been offering customers ETL certified patch panels since 1975, both with advanced technology and 48 years of experience, HCI ensures each customer's demands are met.

Result 169 - 176 of 176
  • For C6/ C6A STP plug
    For C6/ C6A STP plug
    Φ6.5mm

    The integrated boot offers convenience when using it in densely populated blade switches or high-density patch panels. Its slim body seamlessly aligns with the width of the modular plug, ensuring no interference between adjacent ports. The distinguishing feature of this boot is its composition(double-shot), as it is crafted using a dual-material design. The two claws responsible for securely gripping the modular plug are constructed from rigid PC (Polycarbonate) material. Meanwhile, the tail boot is fabricated from a flexible PVC material, enabling free-directional orientation without any constraints. - PC(claws)/PVC(tail boot) UL94V-2 rated - For approximately 6.5mm shielded cable O.D.


  • Patch Panels
    Patch Panels

    Patch Panels are deployed in Equipment/Telecom Room for port distributions and future MOVE, ADD and CHANGE. HCI BP24KHA series are connecting-hardware standard verified, and will guarantee excellent crosstalk cancelation when making interconnection in the telecommunication room. SP24ZM series provide Snap-in Keystone Type combination which also meet connecting-hardware standard. Feed-through RJ-45 to RJ-45 type patch panels are getting more and more popular recently because they offer Plug-and-Play convenience when connecting to switches and routers. A common fact is Feed-Through panels downgrade the transmission performance in the whole cabling. Yes and No. YES – there is no component-rated Feed-through panel in the world because there’s no standard for it. NO – choosing a good Feed-Through panel SP482KICS would give you equivalent performance that supports all kinds of inter-connection or cross-connection you may possibly encounter on the sites. HCI offers U.S. patented Patch Panels which comply with dimensional requirements of ANSI/TIA-1096-A (former FCC Part 68), EIA-310 specification for racks & panels and product reliability requirements of IEC 60603-7 for RJ45 8-way connector. Transmission performance is verified by Intertek’s ETL from the premium ISO/IEC 11801 Ed. 2.2 Cat 6a to ANSI/TIA 568.2-D Cat 6A. And the production quality is quarterly monitored and tested by Intertek’s ETL to retain the certificate validation. Various options are available in: Application: Shielded/Unshielded, Configured Modular Type/Snap-in Keystone Type Connection Type: “RJ-45 to IDC” or “RJ-45 to RJ-45(Feed-through)” Cabling Category: ISO-11801 Cat 6a, Cat 6A, Cat 6 and Cat 5e Transmission Performance: Component-Rated or Channel-Compliant Depends on different project requirements, you can freely choose the favorable ones to satisfy your actual needs.


  • UTP Blank Panel
    UTP Blank Panel

    Cat 6A Snap-in Patch Panels HCI SP24ZM series provide Snap-in Keystone Type combination which meets connecting-hardware standard. SP24ZM is designed to work with KHA & KVA series as combo package to achieve ISO/IEC-11801 and ANSI/TIA 568.2-D Cat 6a Component-Rated performance. It specially features “3-dimensional structure” for Alien Crosstalk mitigation. Neighboring ports are configured 3-dimensionally apart. The spacing between ports is optimized so as to contribute the best geometry that avoids the external unwanted signals. This technique is US 9667004 B1 Patented. Cat 6 / Cat 5e Front-Access Patch Panel HCI SP24F series provide Snap-in Keystone Type combination which meets connecting-hardware standard. SP24F features Front-Access design. Simply rotate the hinged I.D. cover to remove the 6-in-1 bezel at front. It offers the convenience for pulling bulk cables from the rear when the panel is fixed on rack. Anyone would prefer terminating keystone jacks at the bright side of the room rather than the dim corner of the cabinet. Just put the 4 packs of jack-loaded bezels back to the panel when the termination is done. Easy and neat! This unique design is US 7278880 B1 Patented.


  • STP Blank Panel
    STP Blank Panel

    Shielded System is the most recommended for its privilege of EMI prevention & thorough immunity of external noises. Thus 24-port in 1U “shoulder by shoulder” port alignment is no longer a problem. No maximized spacing between each port is needed since alien crosstalk is no longer a problem for shielded connectors. SP24N Series will do the jobs. We can even put 48-port in 1U if we want to take that advantage to the extreme. 48-port in 1U will save a lot of precious rack space in Data Center. SP482 Series are here to solve your problems in dense cabinets.


  • 3D-Staggered Panel
    3D-Staggered Panel

    SP24ZM Snap-in Patch Panels HCI SP24ZM series provide Snap-in Keystone Type combination which meets connecting-hardware standard. SP24ZM is designed to work with KHA & KVA series as combo package to achieve ISO/IEC-11801 and ANSI/TIA 568.2-D Cat 6a Component-Rated performance. It specially features “3-dimensional structure” for Alien Crosstalk mitigation. Neighboring ports are configured 3-dimensionally apart. The spacing between ports is optimized so as to contribute the best geometry that avoids the external unwanted signals. This technique is US 9667004 B1 Patented.


  • 48-port in 1U snap-in Patch Panel with wire management
    48-port in 1U snap-in Patch Panel with wire management

    SP482M Snap-in Patch Panels HCI SP482M series provide Snap-in Keystone Type combination which meets connecting-hardware standard. 48-port in 1U saves precious rack space in Data Center. This high density snap-in patch panel is designed to work with LKVAS & LKVASD series as combo package to achieve ISO/IEC-11801 and ANSI/TIA 568.2-D Cat 6a Component-Rated performance. The design of LKVAS & LKVASD keystone jacks is covered by both US 9391405 B1 and US 9929480 B1 patents. The former patent discloses the impedance-matching technique for improving Return Loss and compensation methodology to counteract NEXT & FEXT. The later patent utilizes unique toolless termination that retains the twist to the point of termination so as to optimize Cat 6a performance.


  • UTP Panel Mountable
    UTP Panel Mountable

    HCI Panel Mountable Coupler features standard 14.55mm x 16.05mm jack opening and is mountable to any universal 19.20mm (±0.20) height mounting fixtures. The premium 3013AKIC Series offer various Cat 6A options from ISO-11801 ClassEa to TIA-568.2-D Cat 6A channel performance. The patented US 9391405 B1 design features Inductance-offset technique to relieve the disturbance caused by Feed-Through connection. 3013AJIC6S Series will do the jobs in all kinds of Cat 6 and Cat 5e sites. Alternatively, 3013AJUQ Series can be a good solution in certain occasions where wall depth is limited. It rotates RJ-45 female port in 90 degree so the routing direction can be vertically converted.


  • STP Panel Mountable
    STP Panel Mountable

    HCI Panel Mountable Coupler features standard 14.55mm x 16.05mm jack opening and is mountable to any universal 19.20mm (±0.20) height mounting fixtures. Unlike Unshielded Keystone Couplers, Shielded Keystone Couplers provide good immunity against EMI/RFI. Shielded system is still preferable if budget permits. The premium 3013AKICS Series offer various Cat 6A options from ISO-11801 ClassEa to TIA-568.2-D Cat 6A channel performance. It is housed by zinc-alloyed die-cast body which gives the best airtight radiation prevention and robustness. The patented US 9391405 B1 design features Inductance-offset technique to relieve the disturbance caused by Feed-Through connection. 3013AJSI Series feature brass-housing screen which will do the jobs in all kinds of Cat 6 and Cat 5e sites. Alternatively, 3013AJSQ6A Series can be a good solution in certain occasions where wall depth is limited. It rotates RJ-45 female port in 90 degree so the routing direction can be vertically converted.



Result 169 - 176 of 176