-
For 0.90-1.00mm Insulated Conductor
Cable Range: O.D.≦5.5mm
Standard Cat 5e unshielded modular plugs accept 24 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 5.5mm. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
Cable Range: O.D.≦5.5mm
The Pass-Through Cat 5e unshielded modular plugs accept 24AWG to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 5.5mm. The Pass-Through plug gives you the convenience of threading the wires through the end wall and cutting them afterward. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8401 Series Crimping Tool
-
For 0.70-0.80mm Insulated Conductor
Cable Range: O.D.≦5.5mm
The “Small Conductor” Cat 5e unshielded modular plugs accept from 26 to 28AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.70mm to 0.80mm. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
Cable Range: O.D.≦5.5mm
Standard Cat 5e Shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 5.5mm. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
Cable Range: O.D.≦5.5mm
The Pass-Through Cat 5e shielded modular plugs accept from 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 5.5mm. The Pass-Through plug gives you the convenience of threading the wires through the end wall and cutting them afterward. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8401 Series Crimping Tool
-
For 1.05-1.15mm Insulated Conductor
Cable Range: O.D.≦5.5mm
The “Big Conductor” Cat 5e shielded modular plugs accept from 23 to 24AWG, F/UTP solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 5.5mm. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 1.05-1.15mm Insulated Conductor
Cable Range: O.D.≦6.5mm
The “Big Conductor” Cat 5e shielded modular plugs accept from 23 to 24AWG, S/FTP solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
"Single Piece" without loading bar
Standard Cat 6 unshielded modular plugs accept 24 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. Single-piece plug is for those who are equipped with excellent workmanship on the field. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“3pcs”, loading bar + windmill guide
Standard Cat 6 unshielded modular plugs accept 24 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. The “guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“2pcs”, 4-up/4-down loading bar
Standard Cat 6 unshielded modular plugs accept 23 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“2pcs”, 6-up/2-down loading bar
Standard Cat 6 unshielded modular plugs accept 23 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
Cable Range: O.D.≦6.5mm
The Pass-Through Cat 6 unshielded modular plugs accept 24AWG to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. The Pass-Through plug gives you the convenience of threading the wires through the end wall and cutting them afterward. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8401 Series Crimping Tool
-
For 0.95-1.05mm Insulated Conductor
Cable Range: O.D.≦6.5mm
The Snagless Pass-Through Cat 6 unshielded modular plugs accept from 23AWG to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm and cable O.D. less than 6.5mm. “The Snagless” allows easy pulling through crowded distribution frames or cable management trays. “The Pass-Through” enables the threading of all wires through the plug's end wall for subsequent cutting. It must work with 007A8502 Series Crimping Tool for termination and cutting of wires both at once! - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8502 Series Crimping Tool
-
For 1.05-1.15mm Insulated Conductor
Cable Range: O.D.≦6.5mm
The Snagless Pass-Through Cat 6 unshielded modular plugs accept from 23AWG to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. “The Snagless” allows easy pulling through crowded distribution frames or cable management trays. “The Pass-Through” enables the threading of all wires through the plug's end wall for subsequent cutting. It must work with 007A8502 Series Crimping Tool for termination and cutting of wires both at once! - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8502 Series Crimping Tool
-
For 1.00-1.10mm Insulated Conductor
“Single Piece”without loading bar
The “Big Conductor” Cat 6 unshielded modular plugs accept from 24 to 26AWG, U/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.00mm to 1.10mm and cable O.D. less than 5.0mm. Single-piece plug is for those who are equipped with excellent workmanship on the field. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 1.05-1.15mm Insulated Conductor
“2pcs”, 4-up/4-down loading bar
The “Big Conductor” Cat 6 unshielded modular plugs accept from 24 to 26AWG, U/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.0mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“Single Piece”without loading bar
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 5.5mm. Single-piece plug is for those who are equipped with excellent workmanship on the field. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“2pcs”, 4-up/4-down loading bar
Standard Cat 6 shielded modular plugs accept 23 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“2pcs”, 6-up/2-down loading bar
Standard Cat 6 shielded modular plugs accept 23 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
“3pcs”, loading bar + windmill guide
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon
Plug + φ6.7mm Boot + Boot Icon
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon + Cable SR
Plug + φ6.7mm Boot + Boot Icon + Cable SR
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
Cable Range: O.D.≦6.5mm
The Pass-Through Cat 6 shielded modular plugs accept 24AWG to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. The Pass-Through plug gives you the convenience of threading the wires through the end wall and cutting them afterward. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8401 Series Crimping Tool
-
For 0.95-1.05mm Insulated Conductor
Cable Range: O.D.≦6.5mm
The Snagless Pass-Through Cat 6 shielded modular plugs accept from 23AWG to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm and cable O.D. less than 6.5mm. “The Snagless” allows easy pulling through crowded distribution frames or cable management trays. “The Pass-Through” enables the threading of all wires through the plug's end wall for subsequent cutting. It must work with 007A8502 Series Crimping Tool for termination and cutting of wires both at once! - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8502 Series Crimping Tool
- Home Homepage
- This is HCI Company Profile
- Products Data Connectivity
-
Solutions Transmission Category
- UTP - ISO Cat 6a Component-Rated
- STP - ISO Cat 6a Component-Rated
- UTP - ISO-11801 Class Ea Cabling
- STP - ISO-11801 Class Ea Cabling
- UTP - TIA Cat 6A Component-Rated
- STP - TIA Cat 6A Component-Rated
- UTP - TIA Cat 6A Cabling Solution
- STP - TIA Cat 6A Cabling Solution
- UTP - Super Cat 6 Component-Rated
- STP - Super Cat 6 Component-Rated
- UTP - Super Cat 6 Cabling Solution
- STP - Super Cat 6 Cabling Solution
- In the Know Download Catalog
- Contact Us Send us an inquiry