Patch Cord Searched | Innovative modular plug for B2B buyers | HCI

HCI is a leading structured cabling provider in Taiwan since 1975, we have almost 50 years experience in telecommunication OEM/ODM projects.




Best Seller

Patch Cord | Bulk USB coupler purchasing for enterprises | HCI

Located in Taiwan since 1975, HSING CHAU INDUSTRIAL CO., LTD. is a manufacturer of wireless networking components for network installation and maintenance. Their main network infrastructure and connectivity solutions include, Patch Cord, keystone jacks, patch panels, patch cords, modular connectors, RJ45 couplers, wall outlets and faceplates, twisted pair cables, and USB couplers supporting advanced 802.3bt 100W 4PPoE, certified under IEC-60512-99-002, ideal for wholesale buyers who require the latest networking technology.

Enhance your network with HCI's world-class B2B solutions. Our U.S.-certified and patented Keystone Jacks, Patch Panels, and Patch Cords ensure superior quality. Ideal for global business buyers, our Taiwan-made RJ45 couplers and twisted pair cables offer unmatched reliability and performance for bulk purchases. HCI offers unmatched performance in networking hardware. Improve your business connectivity with our trusted, high-quality products.

HCI has been offering customers ETL certified patch panels since 1975, both with advanced technology and 48 years of experience, HCI ensures each customer's demands are met.

Result 97 - 113 of 113
  • Cat 6 SF/TP Molded Type Stranded Round Patch Cord
    Cat 6 SF/TP Molded Type Stranded Round Patch Cord
    SF01MT6B

    Using 26 AWG (0.4mm) stranded wire S/FTP twisted-pair patch cables and shielded plugs. Individual aluminum foil screened balanced elements provides good protection from data errors. Overall braid-screened cable helps to complete a proper ground connection. It allows long runs with less fear of EMI/RFI. Insulated with best grade of PVC or LSZH sheath. U.S. TAA Compliant version available upon request


  • Cat 5e SF/TP Molded Type Stranded Round Patch Cord
    Cat 5e SF/TP Molded Type Stranded Round Patch Cord
    SF01MT5eB

    Using 26 AWG (0.4mm) stranded wire S/FTP twisted-pair patch cables and shielded plugs. Individual aluminum foil screened balanced elements provides good protection from data errors. Overall braid-screened cable helps to complete a proper ground connection. It allows long runs with less fear of EMI/RFI. Insulated with best grade of PVC or LSZH sheath. U.S. TAA Compliant version available upon request


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, loading bar + windmill guide

    Standard Cat 6 unshielded modular plugs accept 24 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. The “guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    Standard Cat 6 unshielded modular plugs accept 23 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 1.05-1.15mm Insulated Conductor
    For 1.05-1.15mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    The “Big Conductor” Cat 6 unshielded modular plugs accept from 24 to 26AWG, U/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.0mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    Standard Cat 6 shielded modular plugs accept 23 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, loading bar + windmill guide

    Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • Plug includes Boot w/Icon
    Plug includes Boot w/Icon
    Plug + φ6.7mm Boot + Boot Icon

    Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • Plug includes Boot w/Icon + Cable SR
    Plug includes Boot w/Icon + Cable SR
    Plug + φ6.7mm Boot + Boot Icon + Cable SR

    Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 1.05-1.15mm Insulated Conductor
    For 1.05-1.15mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    The “Big Conductor” Cat 6 shielded modular plugs accept from 23 to 24AWG, F/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 1.05-1.15mm Insulated Conductor
    For 1.05-1.15mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    The “Big Conductor w/Grounding Bar” Cat 6 shielded modular plugs accept from 23 to 24AWG, F/UTP and S/FTP twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. Grounding is facilitated by the external grounding bar. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, 6-up/2-down load bar + windmill guide

    Standard Cat 6A unshielded modular plugs accept from 24AWG to 26AWG, stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. The “guide” helps to separate each pair and keep its twist ratio. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. This could provide many field installers with exactly what they need to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, loading bar + windmill guide

    Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • Plug includes Boot w/Icon
    Plug includes Boot w/Icon
    Plug + φ6.7mm Boot + Boot Icon

    Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • Plug includes Boot w/Icon + Cable SR
    Plug includes Boot w/Icon + Cable SR
    Plug + φ6.7mm Boot + Boot Icon + Cable SR

    Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 1.35-1.45mm Insulated Conductor
    For 1.35-1.45mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    The “Big Conductor w/Hook” Cat 6A shielded modular plugs are made to accept 23AWG S/FTP foamed wires with accommodation of insulated conductor from 1.35mm to 1.45mm and cable O.D. less than 8.0mm. This could be the plug that accommodates the largest foamed wires on the market so far! 2-piece design. The “4-up/4-down loading bar” is made in two rows. It eases the tension throughout the assembling procedure instead of aligning in a single row. It artfully enlarges the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6A Patch Cord Test Limit”. The external grounding hook is built at the rear for encircling the screened braid of S/FTP cable. The 360-degree shield surrounding favors the screen effectiveness and shield integrity that high-speed Ethernet requires. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • Patch Cords
    Patch Cords

    A patch cord (patch lead or patch cable) is a length of electrical (or optical) cable with a plug on one or both ends, typically refer only to short cords used with patch panels. Devices of different types (i.e.: a switch connected to a computer or a switch to a router) are connected with patch cords. Patch cords are usually produced in many different colors so as to be easily distinguishable, and are relatively short, perhaps no longer than 3 meters.



Result 97 - 113 of 113