Cat6 Searched | Innovative modular plug for B2B buyers | HCI

HCI is a leading structured cabling provider in Taiwan since 1975, we have almost 50 years experience in telecommunication OEM/ODM projects.




Best Seller

Cat6 | Bulk USB coupler purchasing for enterprises | HCI

Located in Taiwan since 1975, HSING CHAU INDUSTRIAL CO., LTD. is a manufacturer of wireless networking components for network installation and maintenance. Their main network infrastructure and connectivity solutions include, Cat6, keystone jacks, patch panels, patch cords, modular connectors, RJ45 couplers, wall outlets and faceplates, twisted pair cables, and USB couplers supporting advanced 802.3bt 100W 4PPoE, certified under IEC-60512-99-002, ideal for wholesale buyers who require the latest networking technology.

Enhance your network with HCI's world-class B2B solutions. Our U.S.-certified and patented Keystone Jacks, Patch Panels, and Patch Cords ensure superior quality. Ideal for global business buyers, our Taiwan-made RJ45 couplers and twisted pair cables offer unmatched reliability and performance for bulk purchases. HCI offers unmatched performance in networking hardware. Improve your business connectivity with our trusted, high-quality products.

HCI has been offering customers ETL certified patch panels since 1975, both with advanced technology and 48 years of experience, HCI ensures each customer's demands are met.

Result 97 - 120 of 134
  • Compact Size
    Compact Size
    88TS52G46ATK

    The 88TS52G46ATK is the most compact variant in the 88TS52G product family. Its small size offers the advantage of easy installation in nearly any limited space encountered at various sites. While it features a shortened grounding area compared to traditional plugs with robust cable glands, it is adequate for providing protection against common mode signals in most commercial building environments. With proper grounding procedures in place, it is capable of providing sufficient protection with acceptable electromagnetic compatibility. Similar to other variants in the 88TS52G product family, the 88TS52G46ATK maintains exceptional performance and ensures that the body length does not compromise the transmission speed it is designed to deliver. This plug effortlessly meets the requirements for Modular Plug Terminated Link (MPTL) at any cabling length. Additionally, it successfully passes advanced testing with Cat 6A Patch Cord Limit, showcasing its versatility for various applications where modular plugs are utilized. Without a doubt, compliance with the IEEE 802.3bt standard is essential for field termination plugs used in PoE applications. The 88TS52G46ATK plug is fully compatible with high-power 4PPoE, delivering 90W of power from the Power Sourcing Equipment (PSE) and ensuring the receipt of 71.3W at the Powered Device (PD), in accordance with the standard regulations.


  • Cat 6A STP  Field Termination Plug
    Cat 6A STP Field Termination Plug
    88TS52G2A6ATK

    The 88TS52G2A6ATK series incorporates a two-row prewired mechanism, allowing for the convenient routing of each pair through its designated slot and effortless seating. The screw-type rotatable cable gland is specifically designed to accommodate various cable sizes, ranging from 23AWG solid to 26AWG stranded cables, irrespective of whether they are S/FTP, F/FTP, F/UTP, or U/FTP shielded types. Depending on the diameter of the cable, you have the flexibility to adjust the tightness of the attached grounding by screwing it tightly or loosely according to your requirements. The plug features a free-directional cable entrance that can easily adapt to the incoming cable. Regardless of whether the cable is routed from the top or the sides, you have the flexibility to adjust the cable patch by closing the two-piece guiding lids and rotating them as needed. The plug is compliant with the rigorous standards of IEC 60512-99-002, which guarantee its durability even during numerous mating cycles under electrical load. This compliance aligns with the compatibility requirements set forth by IEEE 802.3bt. The shielded angled type plug is designed to support 4PPoE Class 8 power levels, enabling the transmission of up to 90W of power from the Power Sourcing Equipment (PSE) to the Powered Device (PD) over four twisted pairs. Moreover, the HCI 88TK series plugs are compliant with IEC 60512-99-002 standards, ensuring durability during mating cycles under electrical load, in accordance with the compatibility requirements of IEEE 802.3bt.


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    "Single Piece" without loading bar

    Standard Cat 6 unshielded modular plugs accept 24 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. Single-piece plug is for those who are equipped with excellent workmanship on the field. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, loading bar + windmill guide

    Standard Cat 6 unshielded modular plugs accept 24 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. The “guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    Standard Cat 6 unshielded modular plugs accept 23 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “2pcs”, 6-up/2-down loading bar

    Standard Cat 6 unshielded modular plugs accept 23 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    Cable Range: O.D.≦6.5mm

    The Pass-Through Cat 6 unshielded modular plugs accept 24AWG to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. The Pass-Through plug gives you the convenience of threading the wires through the end wall and cutting them afterward. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8401 Series Crimping Tool


  • For 0.95-1.05mm Insulated Conductor
    For 0.95-1.05mm Insulated Conductor
    Cable Range: O.D.≦6.5mm

    The Snagless Pass-Through Cat 6 unshielded modular plugs accept from 23AWG to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm and cable O.D. less than 6.5mm. “The Snagless” allows easy pulling through crowded distribution frames or cable management trays. “The Pass-Through” enables the threading of all wires through the plug's end wall for subsequent cutting. It must work with 007A8502 Series Crimping Tool for termination and cutting of wires both at once! - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8502 Series Crimping Tool


  • For 1.05-1.15mm Insulated Conductor
    For 1.05-1.15mm Insulated Conductor
    Cable Range: O.D.≦6.5mm

    The Snagless Pass-Through Cat 6 unshielded modular plugs accept from 23AWG to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. “The Snagless” allows easy pulling through crowded distribution frames or cable management trays. “The Pass-Through” enables the threading of all wires through the plug's end wall for subsequent cutting. It must work with 007A8502 Series Crimping Tool for termination and cutting of wires both at once! - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8502 Series Crimping Tool


  • For 1.00-1.10mm Insulated Conductor
    For 1.00-1.10mm Insulated Conductor
    “Single Piece”without loading bar

    The “Big Conductor” Cat 6 unshielded modular plugs accept from 24 to 26AWG, U/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.00mm to 1.10mm and cable O.D. less than 5.0mm. Single-piece plug is for those who are equipped with excellent workmanship on the field. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 1.05-1.15mm Insulated Conductor
    For 1.05-1.15mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    The “Big Conductor” Cat 6 unshielded modular plugs accept from 24 to 26AWG, U/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.0mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “Single Piece”without loading bar

    Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 5.5mm. Single-piece plug is for those who are equipped with excellent workmanship on the field. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    Standard Cat 6 shielded modular plugs accept 23 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “2pcs”, 6-up/2-down loading bar

    Standard Cat 6 shielded modular plugs accept 23 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, loading bar + windmill guide

    Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • Plug includes Boot w/Icon
    Plug includes Boot w/Icon
    Plug + φ6.7mm Boot + Boot Icon

    Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • Plug includes Boot w/Icon + Cable SR
    Plug includes Boot w/Icon + Cable SR
    Plug + φ6.7mm Boot + Boot Icon + Cable SR

    Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    Cable Range: O.D.≦6.5mm

    The Pass-Through Cat 6 shielded modular plugs accept 24AWG to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. The Pass-Through plug gives you the convenience of threading the wires through the end wall and cutting them afterward. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8401 Series Crimping Tool


  • For 0.95-1.05mm Insulated Conductor
    For 0.95-1.05mm Insulated Conductor
    Cable Range: O.D.≦6.5mm

    The Snagless Pass-Through Cat 6 shielded modular plugs accept from 23AWG to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm and cable O.D. less than 6.5mm. “The Snagless” allows easy pulling through crowded distribution frames or cable management trays. “The Pass-Through” enables the threading of all wires through the plug's end wall for subsequent cutting. It must work with 007A8502 Series Crimping Tool for termination and cutting of wires both at once! - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8502 Series Crimping Tool


  • For 1.05-1.15mm Insulated Conductor
    For 1.05-1.15mm Insulated Conductor
    Cable Range: O.D.≦6.5mm

    The Snagless Pass-Through Cat 6 shielded modular plugs accept from 23AWG to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. “The Snagless” allows easy pulling through crowded distribution frames or cable management trays. “The Pass-Through” enables the threading of all wires through the plug's end wall for subsequent cutting. It must work with 007A8502 Series Crimping Tool for termination and cutting of wires both at once! - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8502 Series Crimping Tool


  • For 1.05-1.15mm Insulated Conductor
    For 1.05-1.15mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    The “Big Conductor” Cat 6 shielded modular plugs accept from 23 to 24AWG, F/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 1.05-1.15mm Insulated Conductor
    For 1.05-1.15mm Insulated Conductor
    “2pcs”, 4-up/4-down loading bar

    The “Big Conductor w/Grounding Bar” Cat 6 shielded modular plugs accept from 23 to 24AWG, F/UTP and S/FTP twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. Grounding is facilitated by the external grounding bar. 2-piece design. The “4-up/4-down loading bar” is made in two rows. It allows you to artfully enlarge the spacing between “pin 3 to pin 4” and “pin 5 to pin 6”. In this way, the noise between the blue and green pair can be mitigated so as to easily pass “Cat 6 Patch Cord Test Limit”. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, 6-up/2-down load bar + windmill guide

    Standard Cat 6A unshielded modular plugs accept from 24AWG to 26AWG, stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. The “guide” helps to separate each pair and keep its twist ratio. The “6-up/2-down loading bar” is made in two rows. It facilitates moving the green pair away from the other pairs. This could provide many field installers with exactly what they need to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application


  • For 0.90-1.00mm Insulated Conductor
    For 0.90-1.00mm Insulated Conductor
    “3pcs”, one-row load bar + windmill guide

    Standard Cat 6A unshielded modular plugs accept from 24AWG to 26AWG, stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. Effective pair separation and maintaining the twist ratio are made possible by the "windmill guide". Together with the “loading bar” attached to it so each wire can be trimmed flush and steadily seated. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application



Result 97 - 120 of 134